1 Scope
1.1 This standard applies to pneumatic directional control valves mounted in a valve island, whose solenoids are
directly energized through a single, multi-wire cable that is secured to the valve island with an electrical connector. It
does not apply to a fieldbus system.
1.2 This standard provides a means to identify the stations in a valve island and the solenoids located in a station, in
order that they may be identified for control purposes.
1.3 The standard also provides an association between the solenoids in their stations, and the pins/sockets in the
electric connector for the valve island.
1.4 The standard defines a code to facilitate communications of the valve island solenoid connections.